Roadmap Samples: Difference between revisions

From PRA Workforce Development
Jump to navigation Jump to search
m (1 revision imported)
No edit summary
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
==Fire PRA Roadmap==
==Fire PRA Roadmap==__FORCETOC__
 
[[File:FPRA.png]]
[[File:FPRA.png]]


Line 20: Line 19:
|FR-6  ||Identify spurious operation of equipment ||C-20 ||6 || [[Recurring Applications|Recurring Applications]] || MSPI, Maintenance Rules
|FR-6  ||Identify spurious operation of equipment ||C-20 ||6 || [[Recurring Applications|Recurring Applications]] || MSPI, Maintenance Rules
|- style= "text-align:left;"
|- style= "text-align:left;"
|FR-7 ||Identify credited equipment from App R ||Reserved for Future Development ||7 || [[One-time Applications|One-time Applications]] || Significance Determination Process, License Amendment Request
|FR-7 ||Identify credited equipment from App R || Reserved for Future Development ||7 || [[One-time Applications|One-time Applications]] || Significance Determination Process, License Amendment Request
|- style= "text-align:left;"
|- style= "text-align:left;"
| FR-8 || Identify fire scenarios || C-20 ||style="background-color:#CCCCCC;"| '''Identifier''' ||style="background-color:#CCCCCC;"| '''Skillset Description''' ||style="background-color:#CCCCCC;"| '''Courses'''
| FR-8 || Identify fire scenarios || C-20 ||style="background-color:#CCCCCC;"| '''Identifier''' ||style="background-color:#CCCCCC;"| '''Skillset Description''' ||style="background-color:#CCCCCC;"| '''Courses'''
Line 48: Line 47:


==SFCP Roadmap==
==SFCP Roadmap==
[[File:SFCP.png]]
[[File:SFCP.png]]


Line 56: Line 54:
| '''#''' ||'''Skillset Topic'''|| '''Examples'''|| style="width: 7%;background-color:#CCCCCC;"| '''Identifier''' ||  style="background-color:#CCCCCC;"| '''Skillset Description''' || style="background-color:#CCCCCC;"| '''Courses'''|| style="background-color:#CCCCCC;" | '''#''' ||style="background-color:#CCCCCC;" | '''Skillset Topic'''||style="background-color:#CCCCCC;"| '''Examples'''
| '''#''' ||'''Skillset Topic'''|| '''Examples'''|| style="width: 7%;background-color:#CCCCCC;"| '''Identifier''' ||  style="background-color:#CCCCCC;"| '''Skillset Description''' || style="background-color:#CCCCCC;"| '''Courses'''|| style="background-color:#CCCCCC;" | '''#''' ||style="background-color:#CCCCCC;" | '''Skillset Topic'''||style="background-color:#CCCCCC;"| '''Examples'''
|- style= "text-align:left;"
|- style= "text-align:left;"
| 1 || [[General PRA|General PRA]] || PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training ||[[ Level 1 PRA|L1-QU-1]] || Quantification Set Up/Model truncation || C-10 ||1 || [[General PRA|General PRA]] || Importance Measures, CCDP and CLERP
| 1 || [[General PRA|General PRA]] || PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training ||[[ Level 1 PRA|L1-QU-1]] || Quantification Set Up/Model truncation || C-8 ||1 || [[General PRA|General PRA]] || Importance Measures, CCDP and CLERP
|- style= "text-align:left;"
|- style= "text-align:left;"
| 2 || [[PRA Software]]  || CAFTA, Phoenix Architect, HRA Calculator ||[[ Level 1 PRA|L1-QU-2]] || Flag File || C-10 ||2 || [[PRA Software|PRA Software]] || CAFTA, Phoenix Architect, HRA Calculator
| 2 || [[PRA Software]]  || CAFTA, Phoenix Architect, HRA Calculator ||[[ Level 1 PRA|L1-QU-2]] || Flag File || C-8 ||2 || [[PRA Software|PRA Software]] || CAFTA, Phoenix Architect, HRA Calculator
|- style= "text-align:left;"
|- style= "text-align:left;"
| 3 || [[Level 1 PRA|Level 1 PRA]] || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty || [[ Level 1 PRA|L1-QU-3]] || Mutually Exclusive File || C-10 ||3 || [[Level 1 PRA|Level 1 PRA]] || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
| 3 || [[Level 1 PRA|Level 1 PRA]] || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty || [[ Level 1 PRA|L1-QU-3]] || Mutually Exclusive File || C-8 ||3 || [[Level 1 PRA|Level 1 PRA]] || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
|- style= "text-align:left;"
|- style= "text-align:left;"
|colspan="3" rowspan="34" style="background-color:#FFF"| ||[[ Level 1 PRA|L1-QU-4]] || Recovery Rule File || C-10 ||4 || [[Level 2 PRA|Level 2 PRA]], [[Internal Flood PRA|Internal Flood PRA]], [[Internal Fire PRA|Internal Fire PRA]] || Containment Event Tree Development, Thermal Hydraulic Success Criteria
|colspan="3" rowspan="34" style="background-color:#FFF"| ||[[ Level 1 PRA|L1-QU-4]] || Recovery Rule File || C-8 ||4 || [[Level 2 PRA|Level 2 PRA]], [[Internal Flood PRA|Internal Flood PRA]], [[Internal Fire PRA|Internal Fire PRA]] || Containment Event Tree Development, Thermal Hydraulic Success Criteria
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-QU-5]] || Cutsets and Delterms || C-10 ||5 || [[Model Rollout|Model Rollout]] || Maintenance Rule, SFCP, 50.69
| [[ Level 1 PRA|L1-QU-5]] || Cutsets and Delterms || C-8 ||5 || [[Model Rollout|Model Rollout]] || Maintenance Rule, SFCP, 50.69
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-QU-6]] || Importance Measures Reports || C-10 ||6 || [[Recurring Applications|Recurring Applications]] || MSPI, Maintenance Rules
| [[ Level 1 PRA|L1-QU-6]] || Importance Measures Reports || C-8 ||6 || [[Recurring Applications|Recurring Applications]] || MSPI, Maintenance Rules
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-QU-7]] || Risk Metrics || Reserved for Future Development ||7 || [[One-time Applications|One-time Applications]] || Significance Determination Process, License Amendment Request
| [[ Level 1 PRA|L1-QU-7]] || Risk Metrics || NA ||7 || [[One-time Applications|One-time Applications]] || Significance Determination Process, License Amendment Request
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-QU-8]] || Model Roll-out || Reserved for Future Development ||style="background-color:#CCCCCC;"| '''Identifier''' ||style="background-color:#CCCCCC;"| '''Skillset Description''' ||style="background-color:#CCCCCC;"| '''Courses'''
| [[ Level 1 PRA|L1-QU-8]] || Model Roll-out || NA ||style="background-color:#CCCCCC;"| '''Identifier''' ||style="background-color:#CCCCCC;"| '''Skillset Description''' ||style="background-color:#CCCCCC;"| '''Courses'''
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-QU-9]] || Sensitivities  || Reserved for Future Development || [[PRA Software|SW-7]] || FRANX Software || Reserved for Future Development
| [[ Level 1 PRA|L1-QU-9]] || Sensitivities  || NA || [[PRA Software|SW-7]] || FRANX Software || NA
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-SOU]] || Uncertainty || C-7, C-10 || [[Recurring Applications|RA-9]] || SFCP || C-21
| [[ Level 1 PRA|L1-SOU]] || Uncertainty || C-6, C-8 || [[Recurring Applications|RA-9]] || SFCP || NA
|- style= "text-align:left;"  
|- style= "text-align:left;"  
| [[ Level 1 PRA|L1-SOU-1]] || Identify sources of uncertainty || C-7, C-10
| [[ Level 1 PRA|L1-SOU-1]] || Identify sources of uncertainty || C-6, C-8
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-SOU-2]] || Perform UNCERT runs || C-10
| [[ Level 1 PRA|L1-SOU-2]] || Perform UNCERT runs || C-8
|- style= "text-align:left;"
|- style= "text-align:left;"
| [[ Level 1 PRA|L1-SOU-3]] || Analyze Results || C-10
| [[ Level 1 PRA|L1-SOU-3]] || Analyze Results || C-8
|}
|}

Latest revision as of 21:29, 5 February 2026

Fire PRA Roadmap

FPRA.png

Intro Courses Fire PRA Proficiency
# Skillset Topic Examples Identifier Skillset Description Courses # Skillset Topic Examples
1 General PRA PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training FR-1 Plant Layout Drawings C-20 1 General PRA Importance Measures, CCDP and CLERP
2 PRA Software CAFTA, Phoenix Architect, HRA Calculator FR-2 Walkdown Documentation C-20 2 PRA Software CAFTA, Phoenix Architect, HRA Calculator
3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty FR-3 Identify fire ignition sources (fixed and transient) C-20 3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
FR-4 Identify power supplies/interlocks/instrumentation C-20 4 Level 2 PRA, Internal Flood PRA, Internal Fire PRA Containment Event Tree Development, Thermal Hydraulic Success Criteria
FR-5 Identify loss of equipment impact and target sets C-20 5 Model Rollout Maintenance Rule, SFCP, 50.69
FR-6 Identify spurious operation of equipment C-20 6 Recurring Applications MSPI, Maintenance Rules
FR-7 Identify credited equipment from App R Reserved for Future Development 7 One-time Applications Significance Determination Process, License Amendment Request
FR-8 Identify fire scenarios C-20 Identifier Skillset Description Courses
FR-9 Identify fire induced failures C-20 SW-7 FRANX Software Reserved for Future Development
FR-10 Identify cables supporting circuits where hot shorts impact those cables C-20 RA-5 NFPA 805 Reserved for Future Development
FR-11 Identify cable routing for credited equipment C-20 Includes Listed Fire PRA Skillsets
FR-12 Analyze overcurrent coordination and protection C-20
FR-13 Apply qualitative screening criteria to remove fire zones/PAUs from quantitative analysis C-20
FR-14 Build the PRM to determine CCDP and CLERP C-20
FR-15 Identify Main Control Room Scenarios (including abandonment scenarios) C-20
FR-16 Perform fire modeling to characterize intensity of fires C-20
FR-17 Evaluate fire growth scenarios including full room burnout C-20
FR-18 Determine target damage criteria C-20
FR-19 Identify classic FP equipment credited by the FPRA to reduce fire impact C-20

SFCP Roadmap[edit]

SFCP.png

Intro Courses Application of QU to SFCP Proficiency
# Skillset Topic Examples Identifier Skillset Description Courses # Skillset Topic Examples
1 General PRA PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training L1-QU-1 Quantification Set Up/Model truncation C-8 1 General PRA Importance Measures, CCDP and CLERP
2 PRA Software CAFTA, Phoenix Architect, HRA Calculator L1-QU-2 Flag File C-8 2 PRA Software CAFTA, Phoenix Architect, HRA Calculator
3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty L1-QU-3 Mutually Exclusive File C-8 3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
L1-QU-4 Recovery Rule File C-8 4 Level 2 PRA, Internal Flood PRA, Internal Fire PRA Containment Event Tree Development, Thermal Hydraulic Success Criteria
L1-QU-5 Cutsets and Delterms C-8 5 Model Rollout Maintenance Rule, SFCP, 50.69
L1-QU-6 Importance Measures Reports C-8 6 Recurring Applications MSPI, Maintenance Rules
L1-QU-7 Risk Metrics NA 7 One-time Applications Significance Determination Process, License Amendment Request
L1-QU-8 Model Roll-out NA Identifier Skillset Description Courses
L1-QU-9 Sensitivities NA SW-7 FRANX Software NA
L1-SOU Uncertainty C-6, C-8 RA-9 SFCP NA
L1-SOU-1 Identify sources of uncertainty C-6, C-8
L1-SOU-2 Perform UNCERT runs C-8
L1-SOU-3 Analyze Results C-8