Fire PRA Roadmap: Difference between revisions

From PRA Workforce Development
Jump to navigation Jump to search
No edit summary
No edit summary
Line 6: Line 6:
| style="width: 4%;" | '''#''' ||style="width: 16%;" | '''Skillset Topic'''|| '''Examples'''|| style="background-color:#CCCCCC;"| '''Identifier''' ||  style="background-color:#CCCCCC;"| '''Skillset Description''' || style="background-color:#CCCCCC;"| '''Courses'''|| style="background-color:#CCCCCC;" | '''#''' ||style="background-color:#CCCCCC;" | '''Skillset Topic'''||style="background-color:#CCCCCC;"| '''Examples'''
| style="width: 4%;" | '''#''' ||style="width: 16%;" | '''Skillset Topic'''|| '''Examples'''|| style="background-color:#CCCCCC;"| '''Identifier''' ||  style="background-color:#CCCCCC;"| '''Skillset Description''' || style="background-color:#CCCCCC;"| '''Courses'''|| style="background-color:#CCCCCC;" | '''#''' ||style="background-color:#CCCCCC;" | '''Skillset Topic'''||style="background-color:#CCCCCC;"| '''Examples'''
|- style= "text-align:left;"
|- style= "text-align:left;"
| 1 || [[General PRA|General PRA]] || PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training ||FR-1 |||Plant Layout Drawings ||C-20 ||1 || [[General PRA|General PRA]] || Importance Measures, CCPD and CLERP
| 1 || [[General PRA|General PRA]] || PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training ||FR-1 |||Plant Layout Drawings ||C-20 ||1 || [[General PRA|General PRA]] || Importance Measures, CCDP and CLERP
|- style= "text-align:left;"
|- style= "text-align:left;"
| 2 || [[PRA Software]]  || CAFTA, Pheonix Architect, HRA Calculator ||FR-2 |||Walkdown Documentation ||C-20 ||2 || [[PRA Software|PRA Software]] || CAFTA, Pheonix Architect, HRA Calculator
| 2 || [[PRA Software]]  || CAFTA, Phoenix Architect, HRA Calculator ||FR-2 |||Walkdown Documentation ||C-20 ||2 || [[PRA Software|PRA Software]] || CAFTA, Phoenix Architect, HRA Calculator
|- style= "text-align:left;"
|- style= "text-align:left;"
| 3 || [[Level 1 PRA|Level 1 PRA]]  || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty ||FR-3 ||Identify fire ignition sources (fixed and transient) ||C-20 ||3 || [[Level 1 PRA|Level 1 PRA]] || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
| 3 || [[Level 1 PRA|Level 1 PRA]]  || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty ||FR-3 ||Identify fire ignition sources (fixed and transient) ||C-20 ||3 || [[Level 1 PRA|Level 1 PRA]] || Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty

Revision as of 23:59, 4 February 2026

FPRA.png

Intro Courses Fire PRA Proficiency
# Skillset Topic Examples Identifier Skillset Description Courses # Skillset Topic Examples
1 General PRA PRA Overview, ASME/ANS PRA Standard Elements, Plant Systems Training FR-1 Plant Layout Drawings C-20 1 General PRA Importance Measures, CCDP and CLERP
2 PRA Software CAFTA, Phoenix Architect, HRA Calculator FR-2 Walkdown Documentation C-20 2 PRA Software CAFTA, Phoenix Architect, HRA Calculator
3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty FR-3 Identify fire ignition sources (fixed and transient) C-20 3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
FR-4 Identify power supplies/interlocks/instrumentation C-20 4 Level 2 PRA, Internal Flood PRA, Internal Fire PRA Containment Event Tree Deveopment, Thermal Hydraulic Success Criteria
FR-5 Identify loss of equipment impact and target sets C-20 5 Model Rollout Maintenance Rule, SFCP, 50.69
FR-6 Identify spurious operation of equipment C-20 6 Recurring Applications MSPI, Maintenance Rules
FR-7 Identify credited equipment from App R NA 7 One-time Applications Significance Determination Process, License Amendment Request
FR-8 Identify fire scenarios C-20 Identifier Skillset Description Courses
FR-9 Identify fire induced failures C-20 SW-7 FRANX Software NA
FR-10 Identify cables supporting circuits where hot shorts impact those cables C-20 RA-5 NFPA 805 NA
FR-11 Identify cable routing for credited equipment C-20 Includes Listed Fire PRA Skillsets
FR-12 Analyze overcurrent coordination and protection C-20
FR-13 Apply qualitative screening criteria to remove fire zones/PAUs from quantitative analysis C-20
FR-14 Build the PRM to determine CCDP and CLERP C-20
FR-15 Identify Main Control Room Scenarios (including abandonment scenarios) C-20
FR-16 Perform fire modeling to characterize intensity of fires C-20
FR-17 Evaluate fire growth scenarios including full room burnout C-20
FR-18 Determine target damage criteria C-20
FR-19 Identify classic FP equipment credited by the FPRA to reduce fire impact C-20