Roadmap Samples

From PRA Workforce Development
Revision as of 21:24, 26 January 2026 by Admin (talk | contribs) (1 revision imported)
Jump to navigation Jump to search

Fire PRA Roadmap[edit]

FPRA.png

Intro Courses Fire PRA Proficiency
# Skillset Topic Examples Identifier Skillset Description Courses # Skillset Topic Examples
1 General PRA PRA Overview, ASME/ANS PRA Standard Elements, Pant Systems Training FR-1 Plant Layout Drawings C-20 1 General PRA Importance Measures, CCPD and CLERP
2 PRA Software CAFTA, Pheonix Architect, HRA Calculator FR-2 Walkdown Documentation C-20 2 PRA Software CAFTA, Pheonix Architect, HRA Calculator
3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty FR-3 Identify fire ignition sources (fixed and transient) C-20 3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
FR-4 Identify power supplies/interlocks/instrumentation C-20 4 Level 2 PRA, Internal Flood PRA, Internal Fire PRA Containment Event Tree Deveopment, Thermal Hydraulic Success Criteria
FR-5 Identify loss of equipment impact and target sets C-20 5 Model Rollout Maintenance Rule, SFCP, 50.69
FR-6 Identify spurious operation of equipment C-20 6 Reoccurring Applications MSPI, Maintenance Rules
FR-7 Identify credited equipment from App R NA 7 One-time Applications Significance Determination Process, License Amendment Request
FR-8 Identify fire scenarios C-20 Identifier Skillset Description Courses
FR-9 Identify fire induced failures C-20 SW-7 FRANX Software NA
FR-10 Identify cables supporting circuits where hot shorts impact those cables C-20 RA-5 NFPA 805 NA
FR-11 Identify cable routing for credited equipment C-20 Includes Listed Fire PRA Skillsets
FR-12 Analyze overcurrent coordination and protection C-20
FR-13 Apply qualitative screening criteria to remove fire zones/PAUs from quantitative analysis C-20
FR-14 Build the PRM to determine CCDP and CLERP C-20
FR-15 Identify Main Control Room Scenarios (including abandonment scenarios) C-20
FR-16 Perform fire modeling to characterize intensity of fires C-20
FR-17 Evaluate fire growth scenarios including full room burnout C-20
FR-18 Determine target damage criteria C-20
FR-19 Identify classic FP equipment credited by the FPRA to reduce fire impact C-20

SFCP Roadmap[edit]

SFCP.png

Intro Courses Application of QU to SFCP Proficiency
# Skillset Topic Examples Identifier Skillset Description Courses # Skillset Topic Examples
1 General PRA PRA Overview, ASME/ANS PRA Standard Elements, Pant Systems Training L1-QU-1 Quantification Set Up/Model truncation C-10 1 General PRA Importance Measures, CCPD and CLERP
2 PRA Software CAFTA, Pheonix Architect, HRA Calculator L1-QU-2 Flag File C-10 2 PRA Software CAFTA, Pheonix Architect, HRA Calculator
3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty L1-QU-3 Mutually Exclusive File C-10 3 Level 1 PRA Fault Tree Development, Success Criteria, HRA, Quantification and Uncertainty
L1-QU-4 Recovery Rule File C-10 4 Level 2 PRA, Internal Flood PRA, Internal Fire PRA Containment Event Tree Deveopment, Thermal Hydraulic Success Criteria
L1-QU-5 Cutsets and Delterms C-10 5 Model Rollout Maintenance Rule, SFCP, 50.69
L1-QU-6 Importance Measures Reports C-10 6 Reoccurring Applications MSPI, Maintenance Rules
L1-QU-7 Risk Metrics NA 7 One-time Applications Significance Determination Process, License Amendment Request
L1-QU-8 Model Roll-out NA Identifier Skillset Description Courses
L1-QU-9 Sensitivities NA SW-7 FRANX Software NA
L1-SOU Uncertainty C-7, C-10 RA-9 SFCP C-21
L1-SOU-1 Identify sources of uncertainty C-7, C-10
L1-SOU-2 Perform UNCERT runs C-10
L1-SOU-3 Analyze Results C-10